QuickSee Free Pro by PlenOptika

Industry-leading handheld autorefraction and keratometry

Deliver better vision care and transform lives using the world’s most accurate handheld autorefractor.

QuickSee Free Pro’s combination of the open view design, wavefront aberrometry, and innovative measurement algorithms produces clinically accurate autorefraction results, comparable to the best desktop autorefractors but in a compact, handheld format.

Get a QuickSee Free Pro demo or try it in your practice for 10 days and see how fast, accurate handheld autorefraction can help you grow your practice.

Request More Information

Open view

Reduces patient accommodation for more reliable measurements

Wavefront aberrometry

Provides the most comprehensive method to measure ocular aberrations and refractive errors

Dynamic measurements

Produces results with high confidence

Affordable autorefraction

As accurate as high-end clinical desktop autorefractors at a fraction of the price

Friendly to all kinds of patients

  • Accessible for patients with mobility issues and/or physical challenges (ADA Compliant)
  • Works with bedbound patients
  • Fogging lenses for pediatric exams

Easy to learn and use

  • Operators can be up and running in minutes
  • Pupil camera aids alignment
  • Accelerates subjective refraction with a more accurate starting point

Strong agreement with subjective refraction

<= 0.25 D: 70-75% of patients

<= 0.5 D: 80-90% of patients (see publications)

Unmatched performance in the clinic and in the field

QuickSee Free Pro’s combination of the open view binocular design, wavefront aberrometry, and dynamic measurements produce clinically accurate autorefraction and keratometry measurements in a durable handheld format perfect for use in the clinic, optical shop, and mobile care – such as senior living centers or school settings.

Other benefits

ADA Compliant

Accessible for patients with mobility issues and/or physical challenges

Subjective-ready measurements in less than a minute

Accelerates subjective refraction with a more accurate starting point
Enables high throughput autorefraction

Handheld

Easy to use anywhere
Patient friendly

Strong agreement with subjective refraction

<= 0.25 D: 70-75% of patients

<= 0.5 D: 80-90% of patients (see publications)

Field durable

Calibration free
Operates in humid and dusty environments
Can be used indoors and outdoors, in most light settings
Includes carrying case
Up to 8 hours continuous use on battery, operates while tethered for charging

"With so many patients to see in a short time, we had to go very fast. QuickSee was a tremendous asset."

Alan Glazier, OD
Shady Grove Eye and Vision Care (Rockville, MD) and ODs on Facebook community leader, who used QuickSee in a mission to hurricane-devastated islands

"A significant bottleneck in giving corrective glasses to the over a billion people who need them is the inability to provide an accurate prescription. There just aren’t enough skilled people available to do this nor the right technology that is accurate, easy to learn, affordable and portable. This indeed is the urgent innovation need of the day to help people see better."

Thulasiraj Ravilla
Director-Operations, Aravind Eye Care System  

"It was for me love at first sight on the equipment that I wanted, and we got it. What the ideal thing of QuickSee is that it's very accurate… QuickSee is the best solution for this that I’ve seen, and the most affordable one."

Bijan Azami
Founder, Two Billion Eyes

Request More Information

Clinical performance specifications​

AUTOREFRACTOR
Pupil size2 to 8 mm
Intended patient population>= 3 years
Accommodation control Open view, Fogging lens (optional)
Cycloplegia requirementNone
Dilation requirementNone
Illumination requirementNone
Acquisition time5, 10 seconds
Spherical range-13D to +10D, increments of 0.01D, 0.125D, 0.25D
Cylindrical range-8D to +8D, increments of 0.01D, 0.125D, 0.25D
Axial range0–180º, increments of 1º, 5º, 10º
Base technology Wavefront aberrometry
KERATOMETER
Radius of curvature5 to 12 mm in 0.01 mm increments
Corneal astigmatism0 D to +/- 8 D (R 5 to 12mm)
CenterDiameter 3.2 mm at Radius of curvature 8 mm
Pupil size measurementDisplayed in advanced refraction metrics, Companion App, and printed results
Request More Information

Technical specifications​

Measurement modes (QuickSee Free Pro)Simultaneous AR and K, AR only, and K only
Display properties2.4-inch LCD, capacitive touch screen, readable outdoors, true color (65,536 colors)
Charger propertiesUSB-C medical grade wall adapter, AC 100 to 240V, 50/60 Hz
Battery 6 hours continuous use +/– 1 hour (10,000 mAh Li-ion);
3 hours charge time (5% - 75%);
5 hours charge time (0% - 100%);
IEC 62133-2:2017 certified
CalibrationFactory calibrated; no field calibration needed
Measurement capacityMeasurement storage capacity: > 10,000 measurements
Regulatory classification
(medical device)
Class I FDA (USA), Class IIa Product CE, MDR Compliant, Class IIa, UKCA, MDR 2002 Compliant
Laser safetyClass 1, IEC 60825-1:2014 certified
Weight< 750 grams / 1.65 lbs
Dimensions30 cm (H) x 5.5 cm (W), 18 cm (L)